SYSTEM Ah (ampere hour) NEEDS
For Communications Systems

 

TYPICAL CURRENT REQUIREMENTS

25 Watt Mobile used as
a Control Station

Transmit

6 – 8 Amps

Receive

1 Amp

100 Watt Repeater

Transmit

20 – 30 Amps

Receive

1 – 2 Amps

100 Watt Repeater

Transmit

50 Amps

Standby

1 – 2 Amps

DUTY CYCLES

In normal day to day service, the typical calculation for fixed station usage is 90-5-5, which means 90% standby, 5% transmit, 5% receive. In an emergency or power lost situation, the 90-5-5 guideline may mean very little. Repeaters may go to 100% duty, trunked systems may operate at maximum capacity, and everybody is paging someone, somewhere. Fixed dispatch station usage may run as high as 50% transmit, 50% receive, with no standby. The table listed below will give some idea of what may be required.

SYSTEM USAGE CHART

% Duty Cycle

90S-5T-5R

60S-20T-20R

50T-50S

100T

FOR 5 HOURS

25 Watt Control Station

2.3 Ah

9 Ah

23 Ah

- -

100 Watt Repeater

- -

20 Ah

55 Ah

150 Ah

Paging System

- -

- -

125 Ah

250 Ah

FOR 10 HOURS

25 Watt Control Station

4.5 Ah

18 Ah

45 Ah

- -

100 Watt Repeater

- -

40 Ah

110 Ah

300 Ah

Paging System

- -

- -

250 Ah

500 Ah

 