MULTI-FUNCTION COMMERCIAL RLP |
|
|
|
RLP-5048
RLP Series
RLP Options Charts
RLP Series Pricing
|
|
RLP-5048
Heavy Duty Rack Mount Power Supply for
220 VAC |
|
|
|

5 1/2”H X 19”W X 13”D
|

Weight - 30 lbs
|
•
High Power 48 VDC Power Supply
•
50 Amps
•
2400 Watts of Output Power at 80% Efficiency
•
Short Circuit / Over Load / Over Voltage / Over Temperature
Protections
•
Usable in Positive or Negative Ground Applications with No Changes
|
|
|
Model Number
RLP-5048 |
Amps (Max)
50 |
Input Voltage
180 - 264 VAC |
Adjustable Output
VDC
48 |
| |
|
|
|
PRICING |
RLP-5048
|
$1500.00 |
|
|
RLP Series
Commercial Rack Mount Power Supplies |
|

Top view with cover
removed
3
1/2”H X 19”W X 13”D
|
Heavy Duty AC to DC
Power Supplies
Premium Features:
• All RLP series power supplies are
enclosed in a ventilated, gold
irridite aluminum chassis 13" deep.
• Front panels are powder-coated aluminum
3-1/2"(H) by 19"(W)
with punch-outs for rack mounting.
• Lightweight, corrosion resistant,
excellent heat dissipation.
• Output connections are 1/4" threaded
studs with nuts. |
•
Large scale VOLT/AMP meter with selector switch, front mounted ON/OFF
switch. A charge status LED is provided when optional charger features
are included.
• AC input voltage is automatically
selected from 90 to 264 VAC/50~60Hz. Provides stable input when AC
mains power fluctuates. This is an excellent selling feature for
domestic and export sales to countries with older power grids. Models
with smart charging (SC option) must be manually set to either 110 or
220 position. SC selector switch is on side of cabinet. No disassembly
required.
• PFC (power factor correction) -This
feature applies only to AC circuits. It is the ratio of real power
(watts) delivered to apparent power VOLT AMPS (VA) or Kilo-volt amps( KVA). In AC circuits, the voltage is a SINE Wave. The current (amps)
is also a Sine Wave. For maximum power to be delivered, the two Sine
Waves must be in correct phase or "lock step." If the two are not in
phase the AC voltage will peak before or after the AC current. This
out of step condition will reduce the real power that can be delivered
to and used by the load. The ratio of real to apparent power is the
POWER FACTOR which is expressed in decimal or percentage. If the real
power is 70 watts but the V/A is 100, the PF is 0.7 or 70 percent. For
example, an incandescent lamp has a PF of .097 or better. An AC motor
is typically 0.75 to 0.8. A poor (low) PF will cause excessively high
current (amps) and heating of the load. Power factor correction
maintains a high PF allowing more efficient use of electricity
resulting in lower power costs, and longer component life.
• Remote Sensing - Regulated power
supplies like the RLP series can sample the DC output voltage at the
load and feed it back to the internal reference voltage of the power
supply. The "regulator" adjusts the output voltage up or down as
needed to compensate for line (voltage) loss between the output of the
power supply and the input of the load, keeping the load input voltage
constant. "Line loss" is a major consideration for installers and
operators whose systems contain equipment with voltage-sensitive
microprocessors where DC voltage fluctuation can scramble programmed
codes and frequencies.
• Remote Control - Remote control is the
ability to bring the RLP series power supply "on-line" from another
location, either automatically or by manual control using low level
signaling, typically 5-volts (TTLogic level.)
• Safety Approvals -The power modules
used in the RLP series are UL Recognized for USA & Canada. They also
have TUV (German) and CE (European) safety approval making them truly
International spec compliant.
Commercial Rack Mount Power Supplies
Heavy Duty AC to DC
Power Supplies |
|

Top view with cover
removed |
• Power
Factor Correction
• Universal Input Voltage 90-264VAC
Automatic Sensing
• Meter: Voltage / Amperage
• Inrush Current Limiting
• Remote Sense / Remote Control
• Short Circuit / Over Load / Over
Voltage / Over Temperature
Protections
• Optional Smart Charge System for
Batteries (Factory Installation)
• Optional Low Voltage Disconnect
(Factory Installation)
• Optional Float Battery Charging System
Using Power Supply |
|
|
|
|
RLP Options Charts |
|
OPTIONS - FACTORY
INSTALLED:
|
BB - Battery back-up system (non-charging) utilizing
diode isolation. A separate charger is required.
BC - Battery back-up
system that includes both diode isolation and float charging.
Uses power from power supply for battery charging.
SC -Smart charging module that monitors batteries for
optimal charging and maintenance. Extends battery life.
Recommended for Deep Cycle or Gel cell batteries. Polarity
protected.
LVD -Low Voltage disconnect for 12~15VDC, 24~29VDC,
48~56VDC systems. Stops battery damage due to over discharging.
Protects equipment that is sensitive to low voltage during
battery operation. Disconnects battery at an adjustable voltage.
Disconnect range is 10.5~12VDC for 12 volt systems; 21~24VDC for
24 volt systems; 46~48VDC for 48 volt systems. |
|
|
|
| |
|
|
|
BC |
BB |
SC |
LVD |
| Model # |
Output
Amps |
VDC Output
Range |
|
Battery
Backup |
Battery
Charger |
Smart
Charging |
Low VDC
Disconnect |
RLP8012
RLP8012BBSCLVD
RLP4012
RLP4012BBSCLVD
RLP4024
RLP4024BBSCLVD
RLP2024
RLP2024BBSCLVD
RLP2048
RLP2048BBSCLVD
RLP1048
RLP1048BBSCLVD
|
80
80
40
40
40
40
20
20
20
20
10
10
|
12~15
12~15
12~15
12~15
24~29
24~29
24~29
24~29
48~56
48~56
48~56
48~56
|
|
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
|
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
|
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
|
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
|
| |
|
|
|
|
|
|
|
|
PRICING: |
| Model Number |
Retail Each |
|
RLP8012
RLP8012BBSCLVD
RLP4012
RLP4012BBSCLVD
RLP4024
RLP4024BBSCLVD
RLP2024
RLP2024BBSCLVD
RLP2048
RLP2048BBSCLVD
RLP1048
RLP1048BBSCLVD |
$850.00
$1250.00
$565.00
$890.00
$850.00
$1250.00
$565.00
$890.00
$850.00
$1250.00
$565.00
$890.00 |
| |
|
|
|
| |