The DIN-LVD-12 is pre-set to disconnect the load at 10.4 VDC. However, to prevent premature or false disconnect when the battery voltage drops below the 10.4 volt threshold a 2-minute timer is started. If the battery recovers to above 10.4 volts, the timer resets and waits. The battery can and will recover if the system is a repeater or remote base station or similar equipment that has a varying demand that fluctuates from low to high current. The 2-minute delay ensures the battery is not disconnected until necessary to prevent damage.

After the AC main power is restored and the battery is recharging, the DIN-LVD-12 will reconnect the load when the battery voltage exceeds 12.5 volts.

Product Specifications

Input Range VDC:
0-15
Disconnect / Reconnect VDC:
10.4 / 12.5
Amps (Max):
75
Weight (lbs):
1.75
Dimensions:
2.75"H x 8"W x 4"D