|
BATTERY MANAGEMENT & CHARGERS |
|
|
|
DCS-N1 Diode Switch for Back-Up Power System
BMS
Series Battery Management Systems
RMBC-RMBB Battery Back Up Modules
DPS Power Source Utility
IQ-4 Smart Charger
SC Series Smart Chargers
MMBC and MMBB Battery Back Up
Modules
|
|
|
|
DCS-N1
Diode Switch for Back-Up Power System |
|
Provides Connection of
2 Power Sources
for
N + 1 Redundancy
Usable with 12 / 24 / 48 VDC Systems
Double Output Protection with Diode
Isolation
Automatic Seamless Transfer of Power
Heavy Duty Posts Input/Output Connectors
Handles 5-75 VDC Up to 50 Amps
19 Rack Mount Battery Back-Up Module |

Weight - 7.5 lbs
31/2H X 19W X 13D
|
|

|
|
DCS-N1 PRICING: |
| Model Number |
Retail Each |
|
DCS-N1 |
$470.00 |
|
|
|
|
BMS
Series
One Rack Unit AC/DC, DC/DC Space
Savers |
|

Weight - 6.5 lbs
13/4H X 19W X 101/2D |
Rack Mount Total
Battery Management
Systems with Smart Charger, LVD
and Diode Isolation System
Each Unit Handles Up To 75 Amps
Only 1 rack unit high (1 Ύ")
Usable with 12 / 24 & 48 VDC Systems
Suggested Battery Capacity: 60 to 120Ah |
|
Total Battery
Management System Includes:
Smart Charger, Low Voltage Disconnect, and Diode Isolation System
Smart Charging for Optimal Charging.
Highly Recommended for Deep Cycle or Gel Cell Batteries
Front Panel Indicator for Battery Status. Battery Polarity Protection
Low Voltage Disconnect. Stops Battery
Damage Due to Overdischarge. Auto Re-Connect When Power
is Restored. Disconnects Battery at an Adjustable Voltage
Diode Isolation System Provides
Isolation and Seamless Transfer to Battery When Power Goes Down.
No Relays to Fail. No "Glitches" to Confuse Processors and Controllers
Input 110 or 220 VAC (Switch
Selectable) Smart Charger |
|
|
|
|
BMS PRICING: |
| Model Number |
Retail Each |
|
BMS-12-75
BMS-24-40
BMS-48-20 |
$435.00
$435.00
$435.00 |
| |
|
|
|
|
|
|
RMBC-RMBB
Battery Back Up Modules |
|

Weight - 1.75 lbs
3 1/2H X 9W X 3D |
Combines with RM Series Power Supplies
to Provide Solid State Battery Back Up Operation
Dual
Schottky Diodes provide protective isolation and seamless
transfer to battery when power goes down. No relays to fail.
Handles up to 75 amps continuous.
Easy mounting on the back of 13.8, 27.5
and 48 volt RM
power supplies.
RMBC automatically provides float
charge, battery maintenance
when power is restored.
RMBB provides dual diode isolation but
without battery charging.
Includes mounting hardware and wiring.
Factory installation available if
ordered with RM power supply,
(please specify).
|
BATTERY RMBC ON RM 5012 LOAD


|
|
RMBB and RMBC PRICING: |
| Model Number |
Retail Each |
|
RMBC
RMBB |
$184.00
$167.00 |
|
|
|
|
DPS
Power Source Utility |
|

|

|
LED
Diagnostic Indicators on All Models
Automatic Shutdown on Low AC Voltage
Rack Mountable with SL-Rack Option
Manual Dual Voltage Capable, Automatic
with Optional
Smart Charge Control Module
(DPS-15 and DPS-30 Models) |
Filtered &
Regulated
DPS series power supplies are filtered and regulated. Units are
normally shipped set for 13.8 volts,
27.5 volts, or 48 volts. The unit will maintain regulation with input
voltages from 96 to 140 VAC.
Lightweight
The DPS-75 is just 9 lbs. Compare that to a competitor's ferro-resonant,
50 amp model at 63 lbs.
Over Temperature Protection
DPS power supplies will detect excessive temperature conditions and
temporarily shut down until a safe operating temperature is reached.
Lower Operating Costs
These switch mode power supplies generate little heat until a 70% load
is applied. That means less energy
use at the site.
Forced Air Cooling
Models DPS-30, 45, 55, 75, 90 and DPS-27-25, and DPS-27-15 have a
thermostatically controlled fan to prevent
heat build up. The fan allows these models to be mounted in nearly any
position, and the forced air cooling
extends component life up to 10 times. Model DPS-15 uses convection
cooling.
Standby Battery Smart Charger /
Maintainer / Controller
Need to charge and maintain a standby battery for powering critical
equipment during AC Mains failures? Need to recharge your backup
battery or batteries in minimum time to be ready for the next adverse
event? The IQ-4 Smart Charger will silently monitor the standby
battery terminal voltage and adjust the DPS output voltage as required
to keep the battery fully charged without destructive over-charging.
The DPS output voltage will automatically be set by the IQ-4 for
optimum charge rate depending upon battery state of charge. When the
battery is fully charged the DPS output will drop to a minimum value
below the trickle charge which stops any over-charging.
Note: The DPS output voltage must be reset to 13.2, 26.4 or 52.8
VDC for use with the IQ-4 or the battery will be over-charged.
Fused Output
DPS power supplies are protected against short circuit or polarity
reversal in the output by easily replaceable
standard automotive type fuses.
IQ-4
External
Smart Charger for DPS Series
Standby Battery Smart Charger / Maintainer /
Controller
Need to charge and maintain a standby battery for powering critical
equipment during AC Mains failures? Need to recharge your backup
battery or batteries in minimum time to be ready for the next adverse
event? The IQ-4 Smart Charger will silently monitor the standby
battery terminal voltage and adjust the DPS output voltage as required
to keep the battery fully charged without destructive over-charging.
The DPS output voltage will automatically be set by the IQ-4 for
optimum charge rate depending upon battery state of charge. When the
battery is fully charged the DPS output will drop to a minimum value
below the trickle charge which stops any over-charging.
Note: The DPS output voltage must be reset to 13.2, 26.4 or 52.8 VDC
for use with the IQ-4 or the battery will be over-charged.
Fused Output
DPS power supplies are protected against short circuit or polarity
reversal in the output by easily replaceable standard automotive type
fuses.

Weight - 4 oz.
2 3/4H X 2 3/4W X 4 1/2D
|
|

|
|
DPS & IQ-4 PRICING: |
| Model Number |
Retail Each |
|
DPS-15
DPS-30
DPS-45
DPS-55
DPS-75
DPS-90
DPS-27-15
DPS-27-25
DPS-48-15
IQ-4 |
$154.00
$200.00
$264.00
$292.00
$450.00
$550.00
$330.00
$405.00
$440.00
$51.00 |
|
|
SC Series
Smart Chargers |
|
|
Unit Monitors
Batteries for Optimal Charging and Maintenance
Highly recommended for Deep Cycle
or Gel Cell Batteries
Extends Battery Life
Indicator Lights for Battery
Condition
110/220 Switch Selectable
Battery Polarity Protection
Approvals: UL, CUL, CE,TUV |

Weight - 2.5 lbs.
2H X 7W X 4D |
|
Manufactured to ISO 9001 Quality Assurance |
|
Model |
Amps
(Cont) |
Input Voltage |
Output VDC |
Sugg. Battery Capacity |
|
SC-12 |
7.2 |
110 or 220 VAC
(Switch
Selectable) |
13.8 |
60 to 120 Ah |
|
SC-24 |
4.3 |
110 or 220 VAC
(Switch
Selectable) |
27.6 |
30 to 60 Ah |
|
SC-48 |
2.2 |
110 or 220 VAC
(Switch
Selectable) |
55.2 |
15 to 30 Ah |
|
|
SC SERIES PRICING: |
| Model Number |
Retail Each |
|
SC-12
SC-24
SC-48 |
$125.00
$125.00
$125.00 |
|
|
|
|
|
PB Series
High Capacity Smart Chargers |
|
3 Stage
Smart Charging for Optimal Care & Maintenance
110/220 Switch Selectable
Passive Power Factor
Correction (PFC) Saves Energy Costs!
Indicator Lights for
Battery Condition
Battery Polarity
Protection |

Weight - 2.5 lbs.
2H X 7W X 4D |
|
Manufactured to ISO 9001 Quality Assurance |
|
Model |
Amps
(Cont) |
Input Voltage |
Output VDC |
Sugg. Battery Capacity |
|
PB-360P-12 |
24.3 |
110 or 220 VAC
(Switch
Selectable) |
14.4 |
60 to 200 Ah |
|
|
|
|
|
|
|
PB-360P-24 |
12.5 |
110 or 220 VAC
(Switch
Selectable) |
28.8 |
20 to125 Ah |
|
|
PB SERIES PRICING: |
| Model Number |
Retail Each |
|
PB-360P-12
PB-360P-24 |
$245.00
$245.00 |
|
|
|
|
|
|
|
MMBC and MMBB
Battery Back Up Modules |
|

2.75 lbs
3.5"H X 7"W X 6"D
|
Combines with DPS Series Power Supplies
to Provide Solid State Battery Back Up
Dual
Shottky Diodes provide protective isolation and
seamless transfer to battery when power goes down.
No relays to fail. |
High capacity, will handle up to
75 amps continuous.
MMBC automatically provides
float charge, battery maintenance when power is restored.
MMBB provides Dual Diode
isolation but without battery charging.
Input voltage range up to 60 VDC
allows operation in 12, 24, or 48 VDC systems. (Initial power supply
voltage should be set to 13.8V for 12V systems, 27.5V for 24V systems
and 55.2V for 48V systems to compensate for voltage drop through the
diodes.) |
|
| |
|
MMBC & MMBB PRICING: |
| Model Number |
Retail Each |
|
MMBC
MMBB |
$258.00
$231.00 |
|